<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15555</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: unable to detect balance weight %d
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_VLF</Text></ListItem>
<ListItem><Text>Trendsetter_VLF</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check for a low value of the NVS parameter "altim bwst" (balance find
timeout).
Verify that sensors are working properly
NOTE:  This error is obsolete in VLF trendsetter version 1.40 and newer.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
This is not an operator serviceable error.  Press resume or reset the
machine to continue production.  Call CreoScitex response center.
</text></DescriptionText>
</OperatorAction>
<Cause>
The firmware was unable to detect the balance weight.  The timeout may
be too short or the balance weight sensor could have failed.
</Cause>
<SeeAlso>